MV-90 MDEF import

The MV-90 MDEF import task allows you to define a file format for exchanging data with other systems. The file format supports current meter and recorder technology and new devices to be developed. The file is built in meter (recorder / site) order sequence so that IEE outputs all channels for a device as one group or data set, with any number of channels per metering device.

Use the following procedure to configure a task template:

  1. Go to System Operations > Task Management > Task Templates.

  2. Use the dropdown menu to select the Task Type and Task Template. (Click Add to create a new task template. For more information, see Adding task templates.)

  3. Configure the Task specific parameters. These parameters are defined after step 5 of this procedure.

  4. Configure the Common task template parameters. For more information, see Task template parameters.

  5. Click Save.

Task specific parameters:

ClosedFile Mask

Defines a file extension or a partial file name that IEE uses to monitor import directories and create export files. Enter a file mask such as .xml when configuring an import or export task template. When a file arrives in the import directory, IEE automatically schedules the file for import if it matches the mask. IEE ignores files that do not match the file mask. When creating an export file, IEE appends this mask to the file name.

ClosedImport Directory

Defines the folder that IEE monitors for incoming files. IEE automatically schedules files that arrive in this directory for import. You define the paths to default import directories in the IEE System Administration workbench. When configuring the import directory parameter in an import task template, enter the file path to the directory that IEE monitors for import files specific to this task. This parameter supports standard IEE macros. Reference as ($ImportDirectory) when configuring a task.

ClosedExternal System

Defines any external system to which IEE configuration data can be associated. In many places this parameter provides you with the dropdown menu to select from the external systems configured in the External System table.

ClosedFull path and name of the import file

Defines the complete path to the import file and name of the import file. Do not use relative paths here.

ClosedOwner of Import Tasks

Defines the user ID associated with a task. By default, this field populates with the user currently logged into IEE.