Direct HHF import adapter

Use the Direct HHF Import Adapter to import MV-90 xi or PROFILE type HHF files. This includes HHF files created by Itron products such as MV-RS, FCS, MVP, MVLT, and MVLT xi, as well as HHF files created by other third party data collection systems. Direct HHF imports interval data and register reads associated with each interval channel and meter event data.

The task template defines the parameters for automatically importing data into IEE. You can also use it to manually import HHF files using the Task Scheduler.

Note: The Direct HHF import limits the import of data to three years from the imported data end time to be within UCE’s max validation range. IEE truncates data if importing more than three years and handles delete overlaps, making sure to import complete/contiguous readings, splitting into several reading groups if necessary.

Use the following procedure to configure a task template:

  1. Go to System Operations > Task Management > Task Templates.

  2. Use the dropdown menu to select the Task Type and Task Template. (Click Add to create a new task template. For more information, see Adding task templates.)

  3. Configure the Task specific parameters. These parameters are defined after step 5 of this procedure.

  4. Configure the Common task template parameters. For more information, see Task template parameters.

  5. Click Save.

Task specific parameters:

ClosedHHF File Name

ClosedExternal System

Defines any external system to which IEE configuration data can be associated. In many places this parameter provides you with the dropdown menu to select from the external systems configured in the External System table.

ClosedImport User

Defines the user ID associated with a task. By default, this field populates with the user currently logged into the system.

ClosedFile Mask

Defines a file extension or a partial file name that IEE uses to monitor import directories and create export files. Enter a file mask such as .xml when configuring an import or export task template. When a file arrives in the import directory, IEE automatically schedules the file for import if it matches the mask. IEE ignores files that do not match the file mask. When creating an export file, IEE appends this mask to the file name.

ClosedImport Directory

Defines the folder that IEE monitors for incoming files. IEE automatically schedules files that arrive in this directory for import. You define the paths to default import directories in the IEE System Administration workbench. When configuring the import directory parameter in an import task template, enter the file path to the directory that IEE monitors for import files specific to this task. This parameter supports standard IEE macros. Reference as ($ImportDirectory) when configuring a task.

ClosedImport Entire File

ClosedRecorder Id Match

ClosedDevice Id Match

ClosedDelete Overlaps

ClosedIgnore Channel Configuration Mismatch

Determines whether to ignore channels that do not have a valid mapping. Select this option when there are more channels collecting data, then mapped in IEE. Enabling this option ensures only channels defined for a meter are importing to IEE.