Digital Output 1 and Digital Output 2
Itron water modules are compatible with all sizes of Digital Output 1 and Digital Output 2 registers and CMAG/EMAG meters.
Cadillac meters are approved for use in the configurations described in Table 12 and Table 13.
Additionally:
-
R1, which is meter flow span setting, is determined by using approximately five m/s as maximum system design velocity.
-
When Pulse Mode is set to Auto, the default for Pulse Width becomes 100 ms.
-
Count Rate (Pulse scaling factor) can always be larger than what is listed for any given meter size. It cannot be smaller and must meet 100 ms pulse width.
-
Pulser ERTs must be programmed to 100ms Pulse seven-digit driver.
The following list describes the water modules with which this register is compatible.