Digital Output 1 and Digital Output 2
Itron water modules are compatible with all sizes of Digital Output 1 and Digital Output 2 registers and CMAG/EMAG meters.
Cadillac meters are approved for use in the configurations described in Table 13 and Table 14.
Additionally:
-
R1, which is meter flow span setting, is determined by using approximately five m/s as maximum system design velocity.
-
When Pulse Mode is set to Auto, the default for Pulse Width becomes 100 ms.
-
Count Rate (Pulse scaling factor) can always be larger than what is listed for any given meter size. It cannot be smaller and must meet 100 ms pulse width.
-
Pulser ERTs must be programmed to 100ms Pulse seven-digit driver.
The following list describes the water modules with which this register is compatible.
-
ERW-0771-423. 60WP-R Pulser, remote
-
ERW-0771-311. 60WP Pulser, five-foot cable
-
ERW-0771-301. 60WP Pulser, inline connector
-
ERW-1300-220. 100WP Pulser, 20-inch cable for register, integral connectors for optional telemetry device and direct connect remote antenna
-
ERW-1300-219. 100WP Pulser, 20-inch cable for register connection, integral connector for optional direct connect remote antenna
-
ERW-1300-212. 100WP Pulser, five-foot cable for register, integral connector for optional telemetry device and direct connect remote antenna
-
ERW-1300-211. 100WP Pulser, five-foot cable for register connection, integral connector for optional direct connect remote antenna
-
ERW-1300-209. 100WP Pulser, integral connectors for register and optional telemetry device and direct mount remote antenna
-
ERW-1300-208. 100WP Pulser, integral connectors for register and optional direct connect remote antenna
-
ERW-1300-320/ERW-1300-420. 100WP+ Pulser, 20-inch cable for register, integral connectors for optional telemetry device and direct connect remote antenna
-
ERW-1300-319/ERW-1300-419. 100WP+ Pulser, 20-inch cable for register connection, integral connector for optional direct connect remote antenna
-
ERW-1300-312/ERW-1300-412. 100WP+ Pulser, five-foot cable for register, integral connectors for optional telemetry device and direct connect remote antenna
-
ERW-1300-311/ERW-1300-411. 100WP+ Pulser, five-foot cable for register connection, integral connector for optional direct connect remote antenna
-
ERW-1300-309/ERW-1300-409. 100WP+ Pulser, integral connectors for register and optional telemetry device and direct mount remote antenna
-
ERW-1300-308/ERW-1300-408. 100WP+ Pulser, integral connectors for register and optional direct connect remote antenna