AMI collection systems code table
The AMI collection systems code table defines values for communications with one or more AMI collection systems. Use the table to assign an external system to the collection system adapter and define the way IEE subscribes to the collection system to receive data. In addition, you have the ability to trigger a manual subscription.
Use the following procedure to configure the AMI Collection Systems Code Table:
-
Go to System Administration > System Admin > Code Table Setup.
-
From the Code Table Selection list, select AMI Collection Systems.
-
Use the Number of rows to insert on add dropdown menu to select the number of blank rows to add to the code table.
-
From the Code Table Setup menu, click Add. The new rows appear in the table.
-
Click
to select each blank row added and configure the following parameters:
-
Enable Checkbox. Determines whether the AMI collection system is enabled.
-
Collection System Adapter. This corresponds to the type of collection system that IEE will be integrated with.
-
External System. Select an external system.
-
Subscribe to Endpoint Data. Determines whether to subscribe to endpoint data.
-
Subscription Status
-
-
Subscribe to Meter Exceptions. Determines whether to subscribe to meter exceptions.
-
Subscription Status
-
-
Auto-Subscribe. Determines whether to automatically subscribe.
-
Auto-Unsubscribe. Determines whether to automatically unsubscribe. Use the following tabs to add constraints to the subscriptions:
Subscriber Addresses Tab
-
Endpoint Data Address. This can be either a URL or an Endpoint (when endpoint and event data is received). This box typically points to the DeviceCommDataImportService.
-
Meter Exceptions Address. This can be either a URL or an Endpoint (when exceptions data is received). This box typically points to the DeviceCommExceptionImportService.
-