Interval length conversion in UCE
You can include interval channels with different interval lengths within a single formula. UCE "rolls up" the intervals to find a common interval length to do the math, and returns results in the interval length you specify in the formula. This resulting interval length is called the "rollup interval," and it must be a multiple of the interval lengths that go into it.
For example, if a formula requires values from a channel with a 15-minute interval and a channel with a 30-minute interval, the rollup interval can be 30 minutes or 60 minutes. It cannot be 45 minutes.