Configure multi-week average estimation routine

Add this estimation routine to an estimation set and enter a Routine ID. The Routine ID must be unique for each routine in the estimation set. Configure the following parameters:

  • Number of reference weeks for week average estimation. Defines the number of weeks to use in calculating average values for estimated reads.

  • All reference weeks must have data. If True, the specified number of reference weeks must all have reference data available, otherwise it skips to the next routine.

  • Number of lookback weeks to find nearest reference weeks if data insufficient. If the required X-week references are not available, the routine searches back for the nearest X weeks references.

    The following example shows an estimation set with several multi-week average routines that are configured with different parameters, ordered in priority order from highest to lowest quality, each with a different status to mark as the quality indicator.

For more information about configuring these estimation routines, see Configuring estimation routines: Common parameters.

Related topics: