Tampers and Events by Gas Endpoint

The following table lists tampers/events associated with each gas endpoint type:

Endpoint ERT type Associated tampers/events

25G - 1 foot

0

  • Magnetic
  • Tilt

25G - 2 foot

1

  • Magnetic
  • Tilt

40G/40GB

2

  • Magnetic
  • Tilt

40G Remote

2

  • Cable Cut
  • Cable Cut/Magnetic
  • Tilt

40G Rotary (remote)

2

  • Cable Cut (US models)
  • Cable Cut/Magnetic (Canadian models)
  • Tilt

100G

12

  • Magnetic
  • Tilt

100G Remote

12

  • Cable Cut
  • Cable Cut/Magnetic
  • Tilt

Intelis Gas meter

 

  • Register Error
  • Magnetic Detected
  • Low Battery
  • Reverse Flow Detected
  • Reverse Flow End
  • Valve OK
  • Valve No Comms
  • Extended High Flow Detected
  • Extended High Flow End
  • High Temperature Detected
  • High Temperature End
  • Air In Pipe Detected
  • Air In Pipe End
  • Critical Error (Internal)
  • Right Sizing Started
  • Right Sizing Completed
  • Right Sizing Canceled
  • Flash Error
  • Meter Quiet Mode Exist
  • Entering OW Riva Network Mode
  • Set Battery Params
  • Set Meter Right Sizing Params
  • Key Update
  • Device Not Communicating
  • Load Profile Cleared
  • Manual Time Sync
  • Legally Relevant Event Log Nearly Full
  • Time Sync - Over Threshold Detected
  • Time Sync - Over Threshold End
  • Entering 100S Mode
  • Entering Prover Mode
  • Exiting Prover Mode
  • Flow While Disconnected Detected
  • Button Press/LCD On
  • Flow Sensor Hard Failure
  • Flow Measurement Outside Physical Range Detected
  • Flow Measured Outside Physical Range End
  • Gas Temperature Outside Sensor Range Detected
  • Gas Temperature Outside Sensor Range End
  • Flow Sensor Measurement Error
  • Transducer Error
  • Device Reconfigured
  • Event Log Cleared
  • Configuration Downloaded
  • System Reboot
  • System Restart
  • Improper Installation Detected
  • Disconnect Completed
  • Disconnect Failed
  • Arm Completed
  • Arm Failed
  • Connect Completed
  • Connect Failed
  • Authentication Failed
  • Access Control Failed
  • Key Rollover
  • Key Signing
  • Takeover Package Accepted
  • Takeover Package Rejected
  • Replay Attack Detected
  • RMA Signed Authorization Received
  • Valve Life Nearing Maximum
  • Auto-disconnect Initiated
  • Prover Mode Maximum Time Configuration Changed
  • High Flow Sampling Configuration Changed
  • High Temperature Configuration Changed
  • High Flow Disconnect Enable Changed
  • High Temperature Disconnect Enable Changed
  • Air In Pipe Disconnect Enable Changed
  • Prover Mode Pulse Width Configuration Changed
  • Prover Mode Pulse Weight Configuration Changed
  • PCOP Changed
  • Count Rate Changed
  • Rollover Count Changed
  • Initial Index
  • Image Transfer Initiated (Enabled)
  • Image Transfer Canceled (Disabled)
  • Image Transfer Cancel Failed
  • Image Verification Initiated
  • Image Verification Successful
  • Image Verification Failed
  • Image Activation Initiated
  • Image Activation Successful
  • Image Activation Failed
  • Load Profile Interval Changed
  • Meter Calibrated

OpenWay Riva 500G Module

 

  • Tilt
  • Magnetic
  • Low Battery
  • Tilt Debounce Parameter Changed
  • Cable Cut
  • Cut Cable End
  • Critical Error
  • Flash Error
  • Meter Quiet Mode Exit
  • Entering OW Riva Network Mode
  • Set Battery Params
  • High Flow Threshold
  • Key Update
  • Device Not Communicating
  • Load Profile Cleared
  • Manual Time Sync
  • Time Sync
  • Entering Mobile Mode
  • Device Reconfigured
  • Configuration Downloaded
  • System Reboot
  • Restart
  • Improper Installation Detected
  • Authentication Failed
  • Access Control Failed
  • Key Signing
  • Takeover Package Accepted
  • Takeover Package Rejected
  • Replay Attack Detected
  • PCOMP Changed
  • Count Rate Changed
  • Rollover Count Changed
  • Initial Index
  • Image Transfer Initiated
  • Image Transfer Canceled
  • Image Transfer Cancel Failed
  • Image Verification Initiated
  • Image Verification Successful
  • Image Verification Failed
  • Image Activation Initiated
  • Image Activation Successful
  • Image Activation Failed
  • Legally Relevant Event Log Nearly Full

OpenWay Riva Gas Remote Disconnect (OWR-GRD)

 

  • Tilt
  • Valve Tamper
  • Electronic Tamper

OpenWay Riva Gas Gate Remote Disconnect (OWR-GGRD)

 

  • Cable Cut
  • Auto Shut Off