Workflow Settings for Riva Electricity Devices

These settings manage FDM's interactions with OpenWay Riva and Gen5 Riva electricity and network devices.

Setting

Description

OpenWay Riva Devices

Gen5 Riva Devices

Allow Cross Domain Impersonation

Enables the use of user impersonation when requesting a Signed Authorization token across different domains.

Check this box if your Signed Authorization server is in a different domain from your FDM Client computer.

Do not change. Not used by Gen5 Riva devices.

Allow HDLC Connection

 

Leave this item unchecked. HDLC connections are not supported by any OpenWay Riva devices.

Leave this item unchecked. HDLC connections are not supported by any Gen5 Riva devices.

Allow IP Port Selection

 

Leave this item unchecked. All OpenWay Riva devices use the default TCP/IP port.

Leave this item unchecked. All Gen5 Riva devices use the default TCP/IP port.

Allow Signed Authorization Server Override

Allows the FDM Client user to change the address when requesting a Signed Authorization token.

Check this box only if your environment has multiple instances of OpenWay Collection Manager (OWCM).

Do not change. Not used by Gen5 Riva devices.

Allow TCP Connection

Allows the FDM Client user to log on to a device using a TCP connection.

Ensure that this box remains checked. TCP is the recommended connection method for OpenWay Riva devices.

Ensure that this box remains checked. TCP is the recommended connection method for Gen5 Riva devices.

Allow UDP Connection

 

Leave this item unchecked. UDP is not recommended for use with OpenWay Riva devices.

Leave this item unchecked. UDP is not recommended for use with Gen5 Riva devices.

Allow Wi-Fi Connection

Allows the FDM Client user to log on to a device over a Hosted Wi-Fi connection.

Ensure that this box remains checked. Wi-Fi is required for most OpenWay Riva devices.

Ensure that this box remains checked. Wi-Fi is required for most Gen5 Riva devices.

Authentication Key

128-bit DLMS Authentication key.

Do not change.

Do not change.

Authentication Key (256 bit)

256-bit DLMS Authentication key.

Do not change.

Do not change.

Convert Time to Local

Causes dates and times in the FDM Electricity Workflows to be converted from UTC to the local date and time.

Check this box if you would prefer dates and times to be shown in local time.

Check this box if you would prefer dates and times to be shown in local time.

COSEM Data File Directory

 

Obsolete.

Obsolete.

CRF Directory

 

Obsolete.

Obsolete.

Days of Profile Data

 

Obsolete.

Obsolete.

Default Impersonation Domain

The Domain name used when impersonating a user to request a Signed Authorization token.

If Allow Cross Domain Impersonation is checked, set this value to the domain name that your OWCM uses.

Do not change. Not used by Gen5 Riva devices.

Default IP Port

The default port to use for TCP connections.

Do not change.

Do not change.

Global Encryption Key

128-bit DLMS Encryption key.

Do not change.

Do not change.

Global Encryption Key (256 bit)

256-bit DLMS Encryption key.

Do not change.

Do not change.

Master Key

Master DLMS Encryption key.

Do not change.

Do not change.

Maximum Days of Extended Load Profile

 

Obsolete.

Obsolete.

Maximum Days of Event Data

 

Obsolete.

Obsolete.

Maximum Days of Load Profile

 

Obsolete.

Obsolete.

Meter ID Used in File Name

The meter ID to use when generating the file names of CRF files. This selection is also used inside the CRF file as the unique Endpoint ID.

Type one of the following options. Match the spelling and capitalization exactly.

Electronic Serial Number

Device Serial Number

Network ID (MAC)

Type one of the following options. Match the spelling and capitalization exactly.

Electronic Serial Number

Device Serial Number

Network ID (MAC)

OpenWay Operations Center ID for events

The OpenWay Operation Center ID to include in CRF Event files.

Set as required for importing into your Meter Data Management System (MDM).

Do not change. Not used by Gen5 Riva devices.

Password

Password used for DLMS low level security devices.

Do not change. Not used by OpenWay Riva devices.

Do not change. Not used by Gen5 Riva devices.

Signed Authorization Request Timeout

The number of seconds before a request for a Signed Authorization token times out.

Keep at the default setting unless you have issues requesting Signed Authorization tokens.

Do not change. Not used by Gen5 Riva devices.

Signed Authorization Server

The full address used to request a Signed Authorization token.

Set to the service address for your primary OWCM.

Do not change. Not used by Gen5 Riva devices.

Use Hosted Wi-Fi Windows Service

Enables the use of the Hosted Wi-Fi Windows Service to start the Hosted Wi-Fi connection.

Check this box only if all FDM Client computers have the Hosted Wi-Fi Windows Service installed.

Check this box only if all FDM Client computers have the Hosted Wi-Fi Windows Service installed.

Use Signed Authorization/Secure Logon

Enables the use of Signed Authorization for all devices that support it.

Do not change. All OpenWay Riva devices use Signed Authorization.

Do not change. All Gen5 Riva devices use Secure Logon.

Use Windows Certificate Store

This item reserved for future use.

Leave this box unchecked.

Leave this box unchecked.

Use Wi-Fi Direct Legacy

Enables all computers with Windows 10 or later to use the Wi-Fi Direct Legacy API to start the host-client connection.

Enable when all devices in this Business Unit have been upgraded to firmware that supports Wi-Fi Direct Legacy mode. For more information, see "Hosted Wi-Fi and Mixed Populations of Devices" in the FDM Mobile Application Guide, Chapter 9, "Working with OpenWay Riva Devices."

Do not change. This setting must remain enabled for Gen5 Riva devices.