Test Mode Demand Reset

Use this feature while you are in test mode if you need to wipe out demand quantities or force an end of interval.

At the end of the test mode interval, continuous cumulative and maximum demand values are updated, but cumulative demand remains at zero. To update cumulative demand, perform a demand reset. At this point, cumulative and continuous cumulative demand are updated, and maximum demand is reset to zero.

All energy and demand values are reset to zero when you exit and enter test mode.