MAC / PHY Status
This window specifies some physical attributes of the device.
Field label |
Description |
---|---|
Registered Status |
The application level registration status. This value states whether this device has successfully registered with the OWCM. |
Extended MAC Address |
The full MAC Address of the device. |
Available DSP |
Digital Signal Processor. Displays the hardware capability of the ACT module. Most Riva devices are built with a communications chip that has both RF and PLC capabilities. |
Enabled DSP |
Displays the communications method that has been selected for this device: RF/PLC. Set to choose best possible communications method. RF. Set to Radio Frequency only. PLC. Set to Power Line Carrier only. |
RF Start Frequency |
This value is set in the device during manufacturing. It is based on radio frequency regulations in the utility company’s country or region. |
RF Number of Channels |
The number of radio frequency logical connections that can be used for communication. |
RF Tx Power |
Radio Frequency Transmission Power. Regional regulations state the power at which the radio can transmit. Ranges from a half watt to one watt. It is programmed at time of manufacture. |
Network Time |
UTC network time propagated into the network. |
System Time |
System time of the endpoint. |
RF Modulations SupportedPLC Modulations Supported |
The modulations that this hardware supports, expressed in kilobytes per second. The device chooses the one that works best to communicate with its best parent. |