Units of measurement matrix
Meter units of measurement settings determine the information that is returned when a meter is interrogated. The measurement quantity that is returned by an interrogation is defined in the meter configuration file (meter program). Use the Units of Measurement Matrix as a guideline to set parameters when configuring groups of meters.
CENTRON meter load profiles and registers
Quantity |
Description |
Device class |
Firmware |
Read type / parameter |
Meter configuration requirements |
---|---|---|---|---|---|
Load Profile: |
|
|
|
|
|
VAh d |
VAh delivered |
All |
All Available |
Load Profile / All types of read |
Vah D selected as an energy and load profile channel |
VAh r |
VAh received |
All |
All Available |
Load Profile / All types of read |
Vah R selected as an energy and load profile channel |
Wh d |
Wh delivered |
All |
All Available |
Load Profile / All types of read |
Wh D selected as an energy and load profile channel |
Wh r |
Wh received |
All |
All Available |
Load Profile / All types of read |
Wh R selected as an energy and load profile channel |
Wh net |
Wh net (delivered - received) |
All |
All Available |
Load Profile / All types of read |
Wh Net selected as an energy and load profile channel |
Wh uni |
Wh uni (delivered + received) |
All |
All Available |
Load Profile / All types of read |
Wh Uni selected as an energy and load profile channel |
Vh(a) |
Vh on phase A |
All |
All Available |
Voltage monitoring / All types of read |
Voltage monitoring enabled on phase A |
VARh d |
VARh delivered |
ITR4, ITRD, ITRF, ITRJ |
All Available |
Load Profile / All types of read |
VARh D selected as an energy and load profile channel |
VARh r |
VARh received |
ITR4, ITRD, ITRF, ITRJ, ITRK |
All Available |
Load Profile / All types of read |
VARh R selected as an energy and load profile channel |
VARh net |
VARh net (delivered - received) |
ITR4, ITRF, ITRK |
All Available |
Load Profile / All types of read |
VARh Net selected as an energy and load profile channel |
Registers: |
|
|
|
|
|
Wh d |
Wh delivered |
All |
All Available |
Registers - All types of read |
Wh D is selected as an energy |
Wh r |
Wh received |
All |
All Available |
Registers - All types of read |
Wh R is selected as an energy |
Wh net |
Wh net (delivered - received) |
All |
All Available |
Registers - All types of read |
Wh Net is selected as an energy |
Wh uni |
Wh uni (delivered + received) |
All |
All Available |
Registers - All types of read |
Wh Uni is selected as an energy |
max VA d |
Maximum VA delivered |
ITR1, ITR3, ITR4, ITRE, ITRF, ITRJ, ITRK |
All Available @ factory |
Registers - All types of read |
Vah D is selected as an energy and max VA D is selected as a demand |
max VA r |
Maximum VA received |
ITR1, ITR3, ITR4, ITRE, ITRF, ITRJ, ITRK |
All Available @ factory |
Registers / All types of read |
Vah R is selected as an energy and max VA R is selected as a demand |
max W d |
Maximum W delivered |
All |
All Available |
Registers / All types of read |
Wh D is selected as an energy and max W D is selected as a demand |
max W r |
Maximum W received |
All |
All Available |
Registers / All types of read |
Wh R is selected as an energy and max W R is selected as a demand |
max W net |
Maximum W net (delivered - received) |
All |
All Available |
Registers / All types of read |
Wh Net is selected as an energy and max W Net is selected as a demand |
max W |
Maximum W unidirectional (delivered + received) |
All |
All Available |
Registers / All types of read |
Wh Unidirectional is selected as an energy and max W is selected as a demand |
cum VA d |
Cumulative VA delivered |
ITR1, ITR3, ITR4, ITRE, ITRF, ITRJ, ITRK |
All Available @ factory |
Registers / All types of read |
Vah D is selected as an energy and max VA D is selected as a demand |
cum VA r |
Cumulative VA received |
ITR1, ITR3, ITR4, ITRE, ITRF, ITRJ, ITRK |
All Available @ factory |
Registers / All types of read |
Vah R is selected as an energy and max VA R is selected as a demand |
cum W d |
Cumulative W delivered |
All |
All Available |
Registers / All types of read |
Wh D is selected as an energy and max W D is selected as a demand |
cum W r |
Cumulative W received |
All |
All Available |
Registers / All types of read |
Wh R is selected as an energy and max W R is selected as a demand |
cum W net |
Cumulative W net (delivered - received) |
All |
All Available |
Registers / All types of read |
Wh Net is selected as an energy and max W Net is selected as a demand |
cum W |
Cumulative W unidirectional (delivered + received) |
All |
All Available |
Registers / All types of read |
Wh Unidirectional is selected as an energy and max W is selected as a demand |
ccum VA d |
Continuous cumulative VA delivered |
ITR1, ITR3, ITR4, ITRE, ITRF, ITRK |
All Available @ factory |
Registers / All types of read |
Vah D is selected as an energy and max VA D is selected as a demand |
ccum VA r |
Continuous cumulative VA received |
ITR1, ITR3, ITR4, ITRE, ITRF, ITRK |
All Available @ factory |
Registers / All types of read |
Vah R is selected as an energy and max VA D is selected as a demand |
ccum W d |
Continuous cumulative W delivered |
All |
All Available |
Registers / All types of read |
Wh D is selected as an energy and max W D is selected as a demand |
ccum W r |
Continuous cumulative W received |
All |
All Available |
Registers / All types of read |
Wh R is selected as an energy and max W R is selected as a demand |
ccum W net |
Continuous cumulative W net (delivered - received) |
All |
All Available |
Registers / All types of read |
Wh Net is selected as an energy and max W Net is selected as a demand |
ccum W |
Continuous cumulative W unidirectional (delivered + received) |
All |
All Available |
Registers / All types of read |
Wh Unidirectional is selected as an energy and max W is selected as a demand |
ins V(a) |
Instantaneous voltage on phase A |
All |
All Available |
Registers / All types of read |
None |
max VAR d |
Maximum VAR delivered |
ITR4, ITRD, ITRF |
All Available |
Registers / All types of read |
VARh D selected as an energy and Max VAR D selected as a demand |
max VAR r |
Maximum VAR received |
ITR4, ITRD, ITRF, ITRK |
All Available |
Registers / All types of read |
VARh R selected as an energy and Max VAR R selected as a demand |
max VAR net |
Maximum VAR net (delivered - received) |
ITR4, ITRF, ITRK |
All Available |
Registers / All types of read |
VARh Net selected as an energy quantity and VAR Net selected as a demand. |
cum VAR d |
Cumulative VAR delivered |
ITR4, ITRD, ITRF, ITRJ, ITRK |
All Available |
Registers / All types of read |
VARh D selected as an energy and Max VAR D selected as a demand |
cum VAR r |
Cumulative VAR received |
ITR4, ITRD, ITRF, ITRJ, ITRK |
All Available |
Registers / All types of read |
VARh R selected as an energy and Max VAR R selected as a demand |
cum VAR net |
Cumulative VAR net (delivered - received) |
ITR4, ITRF, ITRK |
All Available |
Registers / All types of read |
VARh Net selected as an energy quantity and VAR Net selected as a demand. |
ccum VAR d |
Continuous cumulative VAR delivered |
ITR4, ITRD, ITRF, ITRJ, ITRK |
All Available |
Registers / All types of read |
VARh D selected as an energy and Max VAR D selected as a demand |
ccum VAR r |
Continuous cumulative VAR received |
ITR4, ITRD, ITRF, ITRJ, ITRK |
All Available |
Registers / All types of read |
VARh R selected as an energy and Max VAR R selected as a demand |
ccum VAR net |
Continuous cumulative VAR net (delivered - received) |
ITR4, ITRF, ITRK |
All Available |
Registers / All types of read |
VARh Net selected as an energy quantity and VAR Net selected as a demand. |
Number of Demand Resets |
The number of demand resets detected by the meter. |
All |
All Available |
Registers / All types of read |
None |
Number of Inversion Tampers |
The number of inversion tampers detected by the meter. |
All |
All Available |
Registers / All types of read |
None |
Number of minutes on battery carryover |
The number of minutes the meter was running on battery carryover. |
All |
All Available |
Registers / All types of read |
None |
Number of Power Outages |
The number of power outages detected by the meter. |
All |
All Available |
Registers / All types of read |
None |
Number of Removal Tampers |
The number of removal tampers detected by the meter. |
All |
All Available |
Registers / All types of read |
None |
Number of times programmed |
The number of times the meter was programmed. |
All |
All Available |
Registers / All types of read |
None |
Cubic feet gas |
Data from a ZigBee-connected gas module. |
All |
All Available |
Home Network Data - All types of read |
Gas module must be properly connected to the HAN. |